paragraph 3 of article 16 of the fire protection law of the people's republic of china stipulates that: conduct a comprehensive inspection of building fire protection facilities at least once a year to ensure that they are in good condition and effective, and the inspection records shall be complete and accurate, and archived for future reference; (fire-fighting facilities refer to fire-fighting power supply and distribution facilities, automatic fire alarm systems and linkage systems, fire hydrant water supply systems, automatic sprinkler systems, smoke and smoke exhaust systems, emergency broadcasting and emergency lighting, and safety evacuation facilities.)
the order of the ministry of public security of the people's republic of china (no. 106) provides for the supervision and administration of fire protection of construction projects, article 21 the construction unit applying for fire protection acceptance shall provide the following materials: (5) fire protection facilities and electrical fire protection technology testing qualification certificates.
the order of the ministry of public security of the people's republic of china (no. 107) provides for the supervision and inspection of fire protection. article 10 in the supervision and random inspection of the entity's performance of statutory fire safety duties, the following contents shall be checked according to the actual situation of the entity: (4) whether the fire protection facilities in the building are regularly carried out the comprehensive inspection, whether fire-fighting facilities, equipment and fire safety signs are regularly inspected and maintained, and whether they are in good condition and effective.
for places and facilities that are prone to static electricity and can cause fire or explosion, measures to prevent or eliminate static electricity should be taken.
noa|noa can provide owners with consulting services such as fire safety consulting based on nfpa, fm datasheet, bs, national laws and regulations, current fire protection technical standards, fire hazard rectification, etc. conduct an on-site inspection of the fire protection system of the existing building and compare it with the specifications (gb, nfpa, fm, bs, etc.) to evaluate its compliance and give suggestions for improvement.
noa|noa provides fire safety inspection and assessment services, including but not limited to:
1. fire design review and consultation
according to the requirements of nfpa, fm datasheet, national laws and regulations, relevant provisions of current fire protection technical standards, owner-owned fire protection technical specifications, etc., review the design of fire protection systems in new buildings, and provide consultation and suggestions, covering the following aspects of scheme design, preliminary design, construction drawing design, etc.
building passive fire protection facilities: including hazard classification, fire resistance rating, layout, fire separation (firewall, fire shutter, fire door, fire window, fire glass, etc.), fire partition, smoke-blocking wall, smoke-proof partition, safe evacuation (number, arrangement and width of safety exits, safe evacuation distance, etc.), interior decoration.
fire protection system: including indoor fire hydrant system, outdoor fire hydrant system, sprinkler system, foam system, fire alarm system, smoke prevention and exhaust system, gas fire extinguishing system, water spray system, fine water mist system, fire separation (protective cooling) water curtain system , foam sprinkler system, others (if any).
2. fire safety inspection, testing and evaluation
fire safety inspections, inspections and assessments include fire protection systems in new buildings or retrofits in existing buildings, on-site installation inspections, or comprehensive acceptance testing of fire protection systems and facilities in buildings that are about to be completed, or in accordance with national laws. the relevant provisions of regulations and current fire protection technical standards shall conduct periodic on-site inspections on the status of fire protection facilities and fire safety management systems in buildings, fire safety management behaviors, fire protection systems and equipment, and building fire protection facilities.
the specific inspection scope is as follows: fire automatic alarm system and linkage control system, fire power supply and distribution system, automatic sprinkler system, fire hydrant system, mechanical pressurized air supply system, smoke prevention and exhaust system, gas fire extinguishing system, water spray fire extinguishing system , foam fire extinguishing system, emergency lighting and evacuation signs, fire emergency broadcasting system and alarm devices, fire elevators, fire separation and other fire protection facilities.
whether it is installation inspection, acceptance test and periodic inspection, our inspection and evaluation system uses a variety of methods and means, including visual inspection, witness testing, testing, drawing inspection, product-related certificate inspection, etc., and also uses a scoring system to provide quantitative evaluate and classify the problems found, and propose feasible solutions. on the basis of the set risk assessment standards, qualitative or quantitative assessment of the risk of each subsystem is carried out, and then the risk of the entire project is assessed. at the same time, it analyzes the types of risks and gives detailed risk control plans.
specific evaluation methods for fire safety management, fire probability and probability, fire severity, and effectiveness of fire protection facilities are as follows: designing fire scenarios, establishing models, simulating fire development and smoke spread through computer software, and using computer software to evaluate personnel simulation of safe evacuation, structural fire resistance assessment, computer software or hand calculation model, calculation of spray start time, calculation of detector start time by computer software or hand calculation model, safety checklist method, building structure fire resistance simulation, event tree method , the accident tree method.
3. maintenance and maintenance of fire protection system
noa|noa provides profound consulting and testing services, and evaluates service quality in strict accordance with national standards and local norms, so that the maintenance and maintenance items of the entire fire protection system are more pertinent, normative, standard and comprehensive. through effective maintenance and maintenance of various fire protection facilities, they are in the best working condition. guaranteed to play its role immediately in the event of an unexpected situation, minimizing damage to personnel and property. the service content covers various fields of fire protection, including: indoor and outdoor fire hydrant systems, automatic sprinkler fire extinguishing systems, automatic fire alarm systems, gas fire extinguishing systems, smoke prevention and exhaust systems, etc.
what are the contents of fire equipment safety inspection?
(1) the variety, specification and quantity of the equipment are applicable, the configuration is reasonable, and the use is convenient;
(2) the equipment has no serious rust, the spare parts are intact, and are in normal use;
(3) the fire water supply water pressure is sufficient to ensure that it can be used within the effective protection range;
(4) the equipment has been implemented to the team or specially-assigned person for maintenance;
(5) have equipment inspection records.
what is included in the channel security check?
(1) the main roads, branch roads, staircases, workshops, and process entrances and exits are barrier-free;
(2) whether fire hydrants and equipment placement points are blocked;
(3) items are placed within the fixed range, and vehicles are not parked indiscriminately;
(4) the setting of signs and markings is clear and reasonable.
what are the contents of electrical equipment safety inspection?
(1) the flammable and explosive production sites must meet the explosion-proof requirements for the installation of electrical equipment;
(2) whether the workshop or department has the phenomenon of disorderly pulling and connecting the wires;
(3) offices, laboratories, and warehouses are turned off before get off work.
what are the contents of the warehouse safety inspection?
(1) warehouse items have identification, quantity, warning signs, and corresponding items are placed according to designated functions;
(2) warehousing materials shall be stored according to the wall distance, stacking distance and spacing, and shall not be overstocked or mixed;
(3) the warehouse has daily ventilation and ventilation, and the cooling measures are well implemented;
(4) the warehouse, factory area, fire fighting equipment and equipment are complete and easy to use, and there are inspection records.